URSA Logo
URSA - Für die Zukunft gut gedämmt

Insulation of a flat ceiling-roof in the two layer system

Guidelines for installing DACH W + DACH P panels in the two-layer system


Required tools and materials:

1. Mineral rockwool insulation panels URSA® DACH W
2. Mineral rockwool insulation panels URSA® DACH P

Guidelines for installing DACH W + DACH P panels in the two-layer system:

A solution that involves mechanical fastening to the trapezoid sheets or concrete flat roof:

Step 1

Unfold insulation foil for flat roofs with 15cm laps and stick the foil laps with the URSA® TOP-DK double-sided adhesive tape.

Step 2

The bottom DACH P panels must be laid perpendicular to the sheet waves, beginning from the eaves.

Step 3

The other layer, DACH W panels, must be laid in a staggered pattern.

Step 4

On the rockwool panels, roofing paper is laid.

Step 5

On the joints of the first layer of roofing paper, mechanical fasteners are fastened to the base (using self-tapping screws for trapezoid sheets). Use fasteners protected against corrosion, with a washer, or telescopic fasteners with a plastic sleeve. The number of fasteners is: 3 fasteners per 1m2 in the middle roof area, 6 fasteners in the edge area, 9 fasteners in the corner area. The anchoring depends on the wind exposure, which should be determined at the design stage.

Step 6

The first layer roofing paper is welded on 10cm wide laps.

Step 7

The top layer is welded all along.

For one-layer paper, PVC foil or EPDM membrane roofing, use the above procedure, except for step 7.